Description as it was

anode materialLi metal foil (counter electrode)
anode material sourceResearcher-confirmed labelling; SI Figure S2a, p.4
cathode materialNone — bare Cu foil (working electrode, no active material)
cathode material sourceResearcher-confirmed labelling for this Li||Cu CE cell; cell schematic in SI Figure S2a, p.4
cell geometry2032 coin cell
cell geometry sourceSI, Electrochemical testing, p.17
cell geometry verbatim2032-type coin cell
cell geometry verbatim sourceSI, Electrochemical testing, p.17
cell id204_01
cell id sourceFilename 204_01_1-1.csv, confirmed by cyc_num_metadata.csv row 204_01
cell typehalf
cell type sourceSI, Electrochemical testing, p.17 (Cu WE vs Li CE, Figure S2a)
electrode area cm22.01
electrode area cm2 sourceComputed from SI-stated 16 mm Cu WE diameter (SI, Electrochemical testing, p.17: 'Cu foil working electrode (WE, 16 mm diameter)'); area = pi*(0.8 cm)^2. Researcher's choice — a per-cell tracking sheet (cyc_num_metadata.csv) lists Cu_d(mm)=15 for this cell, not used here.
electrolyteLiFSI in DME/TTE ("LiFSI DME/TTE LHCE")
electrolyte sourcecyc_num_metadata.csv, row 204_01 (electrolyte=lhce); exact salt concentration/ratio not stated in available SI pages
esra idESRA-CYC-0027
experiment typeCycling
files publictrue
institution codeESRA
materialsCelgard 2325 (separator); Cu (working_electrode, current_collector); LP40 (electrolyte); Li (anode, counter_electrode); LiFSI DME (electrolyte); LiFSI DME/TTE LHCE (electrolyte)
notesLi‖Cu half-cell from a lithium-metal SEI/coulombic-efficiency quantification method study (Steinberg et al., SI nz5c01274). Crimped at 0.82 T (MTI electronic crimper). Coulombic efficiency 97.11%, total capacity loss 0.6119 mAh, ICP-quantified Li inventory loss 0.3178 mAh (from cyc_num_metadata.csv, row 204_01 — the underlying ICP file for this value, 241104_202to204.txt, is not included in this upload), recovery fraction 0.519.
number of cycles12.0
number of cycles sourcecyc_num_metadata.csv, row 204_01 (cyc=12); matches SI's stated target of 12 cycles for LiFSI DME/TTE LHCE, p.19
pi nameMaria K. Chan
projectEnergy Storage Research Alliance
protocol summaryRested 5 h; constant-capacity galvanostatic plating at 0.5 mA/cm2 to 1 mAh/cm2; stripped to 1 V cutoff; 5 min rest between half-cycles
protocol summary sourceSI, Electrochemical testing, p.17
researcher nameMusanna Galib
temperature c25.0
temperature c sourceSI, Electrochemical testing, p.17 ('temperature-controlled incubator at 25°C')
visibilitypublic

Download this version's JSON-LD

Files as they were 2 files · 1.1 MB

204_01_1-1.csv535.6 kB2026-10-27 14:54 UTC
204_04_1-4.csv535.3 kB2026-10-27 14:54 UTC

Size and modification time say whether a file changed since; ESRA does not store checksums.